Control Panels
Int. FACP w/ 2-Line LCD Display, 2 Line Udact Dgtl Comm, R
126 Point Intelligent Fire Alarm Control Panel
126 Point Intelligent Fire Alarm Control Panel
378 Point Intelligent Fire Alarm Control Panel
378 Point Intelligent Fire Alarm Control Panel
Panel Modules
Output Class A Converter Module 4 Circuits
Polarity Reversal & City Tie c/w Supervisory Output
Annunciation
Main Annunciator Chassis c/w 32 Alarm & Trouble LEDs
Main Annunciator Chassis c/w 16 Alarm & Trouble LEDs
Remote Multiplex Annunciator c/w 8 Bi Colored LEDs 4 Gang
Remote Multiplex Annunciator c/w 16 Bi Color. LEDs 4 Gang
Master Graphic Driver Board 32 Supervised Outputs
Remote LCD Annunciator c/w Red Semi Flush Enclosure
Annunciator Semi-Flush Backbox, 1 Module, Red
Panel Accessories
Universal Semi Flush Trim Ring, Black
300 Semi Flush Trim Ring, Black
Features
- Listed to UL 864, 9th edition
- One to Three Addressable SLC Loops supporting 60, 126, or 378 addressable points
- Points can be any combination of Addressable Sensors or Modules
- Supports Ionization Sensors, Photoelectric Sensors, Variable Heat Sensors and Multi–Sensor (Heat/Photo)
- Equipped with 2 line by 20 character back-lit LCD display and numerical keypad
- Integrated UDACT/Digital Communicator
Digital Communicator can be configured for DACT or UDACT mode of operation - Configurable via the front panel, PC Configurator, or remote dial up through the built-in modem
- Sensors can be configured as Alarm, Verified Alarm, Latching or Non-Latching Supervisory, Monitor and Trouble-Only
Modules can be configured as Alarm, Latching Supervisory, Non-Latching Supervisory, Water Flow, Monitor, Trouble, Fire Drill Switch, Signal Silence Switch, Aux Disconnect Switch and Buzzer Silence Switch - Base panel is equipped with Four Class "B" (Style "B") indicating circuits which may be configured as Class "A" (Style "Z") using a Class "A" signal converter module
- Indicating Circuits may be configured as Silenceable or Non-Silenceable for both signals and strobes
- Built-in sync protocols for the following strobe manufacturers: Mircom, Amseco, System Sensor, Gentex, Faraday and Wheelock
- Relay contacts for Common Alarm, Auxiliary/Alarm (Disconnectable), Common Supervisory and Common Trouble
- Configurable Signal Silence Inhibit, Auto Signal Silence and One-Man Walk Test
- Subsequent Alarm, Supervisory, and Trouble operation
- RS-485 Interface for Remote LED and LCD Annunciators,
- Interface for a Remote Trouble Indicator (SRTI-200)
- Two event history logs comprised of a 200 event alarm log for alarm related events and a 200 event general log for all other events
- 5.5 Amp Power Supply
- Optional modules for additional internal relay circuits and City Tie/Polarity Reversal
- Optional trim rings for semi-flush mounting